01✓
Room-by-room load calculation
We run ACCA Manual J loads for every room and ACCA Manual D for duct sizing. That math decides how many zones your system can support and where each damper goes, so the finished system holds setpoints instead of short cycling.
02✓
Motorized damper installation
We cut in and wire motorized dampers sized to your duct runs, then verify each one strokes fully open and closed. Dampers are the moving parts that make zoning work, so we install them where they're serviceable, not buried behind insulation.
03✓
Zone control board and wiring
A zone control board ties your thermostats, dampers and air handler together. We mount it near the air handler, run thermostat wire to each zone, and label every terminal so future service calls are quick.
04✓
Thermostat setup per zone
Each zone gets its own thermostat, wired and configured. We set schedules, calibrate sensors and connect smart controls like Nest, Ecobee or Honeywell so you can manage zones from your phone.
05✓
Airflow commissioning
We measure static pressure, CFM and amp draw at each zone with a psychrometer and clamp meter, then set the board's staging logic. This step is why our zoned systems actually balance instead of just having extra parts.
06✓
Duct repair during install
If we find duct leakage, a crushed flex run or a failing trunk joint, we repair it with mastic and duct sealant as part of the job. Zoning on top of leaky ducts wastes money, so we fix the ductwork first.